ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation | 
| f_dihedral_angle_d | 15.294 | 
| f_angle_d | 0.914 | 
| f_chiral_restr | 0.042 | 
| f_bond_d | 0.007 | 
| f_plane_restr | 0.004 | 
| Sample | 
|---|
| Dispatched protein 'R' conformation | 
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE | 
| Vitrification Instrument | FEI VITROBOT MARK IV | 
| Cryogen Name | ETHANE | 
| Sample Vitrification Details | Wait time 20 seconds, blot time 4 seconds, blotting force 0 | 
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE | 
| Number of Particles | 166203 | 
| Reported Resolution (Å) | 2.5 | 
| Resolution Method | FSC 0.143 CUT-OFF | 
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT | 
| Point Symmetry | C1 | 
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | |||||
| Overall B Value | 69.9 | ||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 66.7 | ||||||||
| Imaging Experiment | 1 | 
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS | 
| Minimum Defocus (nm) | 500 | 
| Maximum Defocus (nm) | 1500 | 
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 | 
| Imaging Mode | BRIGHT FIELD | 
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER | 
| Nominal Magnification | 105000 | 
| Calibrated Magnification | 59880 | 
| Source | FIELD EMISSION GUN | 
| Acceleration Voltage (kV) | 300 | 
| Imaging Details | Automated data collection in SerialEM using 3x3 image shift pattern (one shot per hole), using beam tilt compensation. | 
| EM Software | ||
|---|---|---|
| Task | Software Package | Version | 
| PARTICLE SELECTION | RELION | |
| IMAGE ACQUISITION | SerialEM | |
| CTF CORRECTION | cryoSPARC | |
| CTF CORRECTION | RELION | |
| MODEL FITTING | ISOLDE | |
| MODEL FITTING | Coot | |
| INITIAL EULER ASSIGNMENT | cryoSPARC | |
| FINAL EULER ASSIGNMENT | cryoSPARC | |
| CLASSIFICATION | RELION | |
| RECONSTRUCTION | cryoSPARC | |
| MODEL REFINEMENT | PHENIX | |
| MODEL REFINEMENT | ISOLDE | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 3717941 | |||